9 Alternatively, the front of the cooling unit can be supported by a shelf and a diagonal brace. The shelf can be up to 13.25”(337mm) inches w

Page 3

10 Ventilation OUTSIDE THE CELLAR Proper ventilation is critically important for the proper operation of your CellarPro cooling unit. The Cel

Page 4 - Table of Contents

11the temperature inside the cellar rises above 16.6°C, and turn off when the temperature falls below 14.4°C. In this example, the average temp

Page 5

12 III. Operating Instructions Overview Please follow the instructions in Chapter I prior to turning on your CellarPro cooling unit. CellarPro

Page 6

13 Basic Operation The temperature inside the cellar can be increased or decreased by changing the Minimum Set Point as described later in this

Page 7

14Power On/Off Button Press “Power On/Off” to turn the unit on and off When the “Compressor On” indicator light is on, the Compressor is runnin

Page 8

15 Energy Saver Button To activate and deactivate the “Energy Saver” mode, press the “Energy Saver” button The “Energy Saver” indicator light w

Page 9

16 Advanced Operation CellarPro cooling systems can be programmed with advanced settings to achieve more control over conditions inside the cel

Page 10

17 Standard Protection Mechanisms The cooling unit is programmed to shut down certain components to protect those components, as well as the w

Page 11

18Alarms The cooling unit has both an audible notification and a visual alarm indicator (shown in “red” on the control panel) that are activate

Page 12

1 C O N G R A T U L A T I O N S ! Thank you for purchasing a new CellarPro cooling system. Please take a minute to read through this Owner

Page 13

19 IV. Troubleshooting  The Cooling Unit Runs Constantly The cooling capacity of the cooling unit depends on the thermal load on the wine ce

Page 14

20 The Cooling Unit Is Dripping The cooling unit is designed to remove excess moisture from inside the cellar, which collects in the drip pan

Page 15

21  The LA2 Alarm has been triggered As noted above, the cooling unit is designed to measure the temperature of the condenser coils and, if th

Page 16

22 V. Limited Warranty For two years from the date of purchase, your CellarPro warranty covers all parts and labor to repair or replace any co

Page 17

2 [This page left blank]

Page 18

3 Table of Contents I. Prior to Installation 4 II. Installation Instructions – Wine Cellars 5 III. Operating Instructions 12 IV. Tro

Page 19

4 I. Prior to Installation  Test the unit before installing it. 1. Remove the unit from the box. SAVE THE BOX AND PACKING MATERIALS. 2.

Page 20

5 II. Installation Instructions – Wine Cellars  Specifications Model Dimensions (mm) W x D x H Weight (kg) Operating Amps 1800XT 457 x 419

Page 21

6  Ambient Environment CellarPro cooling units are designed to operate in ambient temperatures between 10.0°C and 29.4°C. They are designed

Page 22

7 We offer a Wine Cellar Modification for cooling units that will be installed in wine cellars (as opposed to wine cabinets.) The Wine Cellar M

Page 23

8 Installation CellarPro cooling units are designed to be installed THROUGH THE WALL. A hole should be cut 0.25”(6.4mm) larger than the dimensi